I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / cs reddy

Bolts are getting loose due to Vibration.
Vibrations may be due to :
a) Misallignment.
b) Improper foundation.
c) Improper Mass Balancing.

Is This Answer Correct ?    10 Yes 1 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / manoj saah

Coupling Misalligment may be major reason.

So do allignment by using Dial Gauge and clearance should
0.05 mm.

Is This Answer Correct ?    2 Yes 1 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / girish

Vibration is a main reason
1. Reduce vibration using vibration isolating mounts
2. use flexble coupling with lock nuts

Is This Answer Correct ?    1 Yes 0 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / rakshit

dumb people .... they have specified 1010 KVA ... which is
very high capacity.... high shear force exists if proper
rated engine is not coupled to generator ,,,, due to high
shear force.. wear in coupling.. wear in coupling... loose
studs... .. also greater vibrations is the cause

Is This Answer Correct ?    1 Yes 0 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / faisalabad

you may use self locking nut as well as suitable grate lock tight according bolts specfication

Is This Answer Correct ?    0 Yes 0 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / pavan

Use lock nuts. Because vibrations are unavoidable (but can
only be minimized), using lock nuts is always safe.

Is This Answer Correct ?    0 Yes 1 No

I have 1010 KVA Generator when i run the DG set for 5 to 6 hours the couplling (couplling joint in..

Answer / nagarajan

I Think u can make use of pins in the nuts at specified
tight point of bolt.

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Mechanical Engineering Interview Questions

hi friends kumar here if anybody of u have " INDRAPRASTHA GAS LIMITED" placement papers than plz send it to me i need it urgently..ok mail id is ashish_me2007@yahoo.co.in

0 Answers  


What type of job are you holding at the moment? What is your desired employment / occupational field

0 Answers   Radisson Blu,


Explain the procedure of charging reciprocating compressor?

0 Answers  


What is the formula for 1 HP of a two-cycle engine?

0 Answers  


what is tool holding system?

1 Answers  






What is the diffrence between four strock and two strock ic engine

14 Answers   Alkem Labs, Mechanical,


where we can get the surfacing modelling project of example to practice in catia.

0 Answers   MRF,


What is shearing?

0 Answers  


Do u know epicyclic gear box?What are the pratical application of epicyclic gear box?

6 Answers  


Can I use motor oil in a hydraulic system?

0 Answers  


What is the advantage and disadvantage of IS 2062 Gr A over IS 2062 Gr B & C

3 Answers   TATA,


what is the regulating speed in a hydraulic coupling

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)