In electrical regulator by using resistance the output
voltage is varied simultateneouly the speed is varied...
But to reduce the the energy loses in the resistor,
electronic regulator is introdueced,which uses triac to
vary the output voltage by varing the firing angle.Which
avoids lose of energy in resistor...
| Is This Answer Correct ? | 155 Yes | 17 No |
Answer / ayyappss
Conventional fan regulator works by the principleof
auto-transformer.
now in modern regulators we using triac to control i.e,by
varying the firing angle, output voltage is varied then
automatically speed can be varied
| Is This Answer Correct ? | 117 Yes | 27 No |
Answer / saurav
The circuit works by varying the firing angle of the Triac..
output voltage is varied then automatically speed can be varied by this..
| Is This Answer Correct ? | 20 Yes | 2 No |
Answer / bhanu gupta
Fan regulator working based on the principle of power control using a Triac.The circuit works by varying the firing angle of the Triac . Resistors and capacitor are associated with this. The firing angle can be varied by varying the value of any of these components. Here register is selected as the variable element . By varying the value of register the firing angle of Triac changes (in simple words, how much time should Triac conduct) changes. This directly varies the load power, since load is driven by Triac. The firing pulses are given to the gate of Triac using Diac.
| Is This Answer Correct ? | 3 Yes | 1 No |
Answer / nk
Electronic fan regulator is an electronic device consisting
of diacs, triacs, potentiometric resistance to provide
stepless control of fan speed. This is an energy saving
device and has advantages over the conventional type of fan
regulators having more energy losses.
These regulators can also be used as a speed regulator for
many other small F.H.P. motors used in mixer, laboratory
solution mixer etc.with appropriate current ratings.
| Is This Answer Correct ? | 18 Yes | 21 No |
Answer / vatsalsharda
by changing the number of turns,flux linkage changes and
thus induced emf changes
| Is This Answer Correct ? | 8 Yes | 43 No |
What about Reactive power.and role of that one?
In case of 3Phase Supply, Voltage R-Earth/Neutral - 220 Y-Earth/Neutral - 220 Z-Earth/Neutral - 220 Total is -> 660Volts Then Why it is said that 3Phase supply is 440
6 Answers Hindustan Unilever Limited,
what is lap & wave winding
Why Neutral Isolation is required?
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
where would be tap changer in transformer & why?
why table fans rotate clockwise .while ceiling in anti clockwise?
What is d main advantage of using double circuit 3 phase transmission ?
Hi, i want to know is meant by power quality? How it can calculated ? How we can improve?
At what speed an electric car can run with 2 HP motor of weighing 400 kg?
In what way does the variable ratio-arm improve the usefulness of the wheatstone bridge?
Why in India only 50hz frequency not 60hz
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)