In electrical regulator by using resistance the output
voltage is varied simultateneouly the speed is varied...
But to reduce the the energy loses in the resistor,
electronic regulator is introdueced,which uses triac to
vary the output voltage by varing the firing angle.Which
avoids lose of energy in resistor...
| Is This Answer Correct ? | 155 Yes | 17 No |
Answer / ayyappss
Conventional fan regulator works by the principleof
auto-transformer.
now in modern regulators we using triac to control i.e,by
varying the firing angle, output voltage is varied then
automatically speed can be varied
| Is This Answer Correct ? | 117 Yes | 27 No |
Answer / saurav
The circuit works by varying the firing angle of the Triac..
output voltage is varied then automatically speed can be varied by this..
| Is This Answer Correct ? | 20 Yes | 2 No |
Answer / bhanu gupta
Fan regulator working based on the principle of power control using a Triac.The circuit works by varying the firing angle of the Triac . Resistors and capacitor are associated with this. The firing angle can be varied by varying the value of any of these components. Here register is selected as the variable element . By varying the value of register the firing angle of Triac changes (in simple words, how much time should Triac conduct) changes. This directly varies the load power, since load is driven by Triac. The firing pulses are given to the gate of Triac using Diac.
| Is This Answer Correct ? | 3 Yes | 1 No |
Answer / nk
Electronic fan regulator is an electronic device consisting
of diacs, triacs, potentiometric resistance to provide
stepless control of fan speed. This is an energy saving
device and has advantages over the conventional type of fan
regulators having more energy losses.
These regulators can also be used as a speed regulator for
many other small F.H.P. motors used in mixer, laboratory
solution mixer etc.with appropriate current ratings.
| Is This Answer Correct ? | 18 Yes | 21 No |
Answer / vatsalsharda
by changing the number of turns,flux linkage changes and
thus induced emf changes
| Is This Answer Correct ? | 8 Yes | 43 No |
explain 100 percent and 95 percent earth faults
how to calculate transformer turn primary & secondary side 11kv to 420v
Can earth resistance be measured without connecting the earth electrode? and should earthing connections be disconnected What is the effect of connecting two cables of different sizes in parallel with supply? Thanks in Advance. I am intrested to get in touch with some tecnocrats/engineers,my mail i.d is : hiremathvijay@rediffmail.com
what is TRCC
WHY LINK NOT A FUSE IN AC CIRCUIT
Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?
What is the function of the serge absorber?
what is the meaning of the parameters labeled on the surge arrestor like 150/20 ???
What are the fire Estingushers use in electrical fire?
what is AB switch???
What is ideal IR values for ground and neutral.
0 Answers Hindustan Power Projects,
Why Generator rotate only clock wise ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)