What is the angle of repose?
No Answer is Posted For this Question
Be the First to Post Answer
how did you spend today
plz send the interview questions in the written test asked by hindustan petroleum corporation ltd.Iam a b>tech in chemical engineering.My written test is on feb 2008.urgent plz.send the questions to avazithraja@rediffmail.com
What's -74C, dew point is better the -70C dew point In draying unit .
oil field interview question
ACCOUNTING AND FINANCIAL ENGINEERING - EXAMPLE 34.21 : The cost of building a biochemical processing plant is increasing due to inflation. Let I = inflation rate, R = nominal interest rate, r = real interest rate. According to Fisher Equation, (1 + r)(1 + I) = (1 + R). According to General Inflation Equation, R = r + I. (a) By assuming that both r and I are fairly small, prove by mathematical calculations that complicated Fisher Equation could be simplified into the General Inflation Equation. (b) By using 2 first order Taylor expansions in the linear approximation, namely 1 / (1 + x) ≈ (1 - x), (1 + x)(1 + y) ≈ 1 + x + y, show by mathematical calculations that (1 + r) = (1 + R) / (1 + I) could be approximated by r ≈ R - I.
Is there a handy way to determine if a horizontal pipe is running full if the flow rate is known?
how can I find out a sulfuric acid recovery plant disigner?
Corenuts technology interview questions
What is the characteristic length for slab?
What does capacitor load means? How does it connect?
what are the reaction between sodium meta bi sulphate and chlorine?
Question 49 - According to rules of thumb in chemical process design, consider the use of an expander for reducing the pressure of a gas when more than 20 horsepowers can be recovered. The theoretical adiabatic horsepower (THp) for expanding a gas could be estimated from the equation : THp = Q [ Ti / (8130a) ] [ 1 - (Po / Pi) ^ a ] where 3 ^ 3 is 3 power 3 or 27, Q is volumetric flowrate in standard cubic feet per minute, Ti is inlet temperature in degree Rankine, a = (k - 1) / k where k = Cp / Cv, Po and Pi are reference and systemic pressures respectively. (a) Assume Cp / Cv = 1.4, Po = 14.7 psia, (temperature in degree Rankine) = [ (temperature in degree Celsius) + 273.15 ] (9 / 5), nitrogen gas at Pi = 90 psia and 25 degree Celsius flowing at Q = 230 standard cubic feet per minute is to be vented to the atmosphere. According to rules of thumb, should an expander or a valve be used? (b) Find the outlet temperature To by using the equation To = Ti (Po / Pi) ^ a.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)