Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


in HPLC injection volume is increase ,R.T will increase ?

Answers were Sorted based on User's Feedback



in HPLC injection volume is increase ,R.T will increase ?..

Answer / b.gangatharan

In hplc area will increase when injection volume is increased.But rt will not increase or change.

Is This Answer Correct ?    27 Yes 1 No

in HPLC injection volume is increase ,R.T will increase ?..

Answer / srikar_22

Increasing sample volume did not show any affect on rt

Is This Answer Correct ?    5 Yes 1 No

in HPLC injection volume is increase ,R.T will increase ?..

Answer / ravi1234

There will be no relation Between Inj Volume and Retention time.If Injection Voulme Increases Area of Peak Changes..Not RT.

Is This Answer Correct ?    2 Yes 0 No

in HPLC injection volume is increase ,R.T will increase ?..

Answer / bindeshwar prasad

Whenever sample concentration will increases there is chance to slight decrease in Rt with respect to lower concentrations Rt.

Is This Answer Correct ?    2 Yes 2 No

in HPLC injection volume is increase ,R.T will increase ?..

Answer / sachin

because of more sample concentration peak will take time to elute.

Is This Answer Correct ?    7 Yes 18 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the Bracketing & Matrixing.

8 Answers   Dr Reddys, Ranbaxy,


what is mean by theoritical plates(not formula) ?

4 Answers   Micro Labs,


how do you established the RRF for unknown impurity

6 Answers   Square Pharma,


Why 162 mg NaOH used for 1N volumetric solution in 150 ml water then 54.5 ml diluted with 1000 ml

0 Answers  


What is Fourier Transform Spectrosopy?

5 Answers   Aurobindo, Hetero, Lupin,


How to establish pKa for a new API molecule ?

2 Answers   Neuland, Sun Pharma,


how much wave length of Soduim vapour lamp used in polarimeter

2 Answers   Reddy Labs, Torrent Pharma,


Why only lead standard solution is uesd to perform heavy metal test.

2 Answers   Reddy Labs,


What is the use of tailing factor ?

2 Answers  


Why 10%,20%,30% Sucrose solution is used for the calibration of polarimeter?

5 Answers   Cipla, LGC Promochem,


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

0 Answers   Cipla, Rampex Labs,


what is third integration

0 Answers   Orchid,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)