in HPLC injection volume is increase ,R.T will increase ?
Answer Posted / bindeshwar prasad
Whenever sample concentration will increases there is chance to slight decrease in Rt with respect to lower concentrations Rt.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately
can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?
what is mean by ambient temperature?
when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.
for heavy metal test lead used in which form pure form or any other form for preparation of lead standard sol
What is similarity factor?
mode of absorption in alimentary canal?
What is importance of pH in the Heavy metal test and How it effect on the test results?
If combination product how require to identify which imp is of which api?
My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards
what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?
What is stray light in uv what are units for stray light
A ha tc is actual defination of retention time?
In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.
how we can identify the impurity is coming below loq at transfering site?