Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How decided 10 ppm standard solution in Swab, rinse method.?

Answers were Sorted based on User's Feedback



How decided 10 ppm standard solution in Swab, rinse method.? ..

Answer / venkat narayana

As per your standard test procedure,you decide yours specification, batch to batch (i.e same product)product change over 100 ppm standard we prepared and batch to another batch(i.e. product change) we have prepared 10 ppm standard

Is This Answer Correct ?    0 Yes 0 No

How decided 10 ppm standard solution in Swab, rinse method.? ..

Answer / kalyan

First we have to prepare 10 ppm standard solution with the respective solvent then we have to determine the abosorbance of that std by using uv after that we have to find the rinsed or swab sample absorbance by usig uv then we can calculate the result using the formula:(sample absorbance/standard absorbance)*10 then we will get the result in ppm

Is This Answer Correct ?    7 Yes 9 No

Post New Answer

More Analytical Chemistry Interview Questions

why we are calibrating autopolarimeter with quartz control plates

1 Answers  


hi i am m.sc organic chem and complete analytical lab tech dipolma now job in qc many time ask question you in m.sc organic why job in qc please help me i can not give proper ans please tell me

3 Answers   Arch Pharmalabs, Natco,


How you develop a method in HPLC?

0 Answers   CU, Perrigo, Wockhardt,


What is the main difference between ODS1 and ODS2 Hplc column.

0 Answers   Indoco Remedies,


What is zero water in TOC Analysis?

1 Answers   Orchid,


What is related substance by HPLC impurity limits as per USP?

0 Answers  


what is end capping in hplc coulmn

2 Answers   Lupin, Zydus Cadila,


Why dissolution test apparatus calibration with salycilic acid tablets was stopped by FDA&USP from the year of 2009?

1 Answers   Aurobindo,


how can you decide API molucule acedic or basic compound by test?

2 Answers   Posh Chemicals,


Any molecule is filing for ANDA purpose, what are the dissolution requirements / specifications needed ?

1 Answers   IPCA,


One Raw material failed assay test is there any chance for failing purity of that material ?

7 Answers   Mylan,


Why we are using only KBr in IR spectrometer why not KCl

10 Answers   Dr Reddys,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)