Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How decided 10 ppm standard solution in Swab, rinse method.?

Answer Posted / kalyan

First we have to prepare 10 ppm standard solution with the respective solvent then we have to determine the abosorbance of that std by using uv after that we have to find the rinsed or swab sample absorbance by usig uv then we can calculate the result using the formula:(sample absorbance/standard absorbance)*10 then we will get the result in ppm

Is This Answer Correct ?    7 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to set analyticl specification for combination products?

718


How to decide assay range for non pharmacopeial API analysis by HPLC? Could you give me any reference for same e.g Guidelines or Paper publications?

3338


can i use hplc detector to uplc and why?

2271


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2581


Why we use potassium dichromate in uv calibration Exact reason behind it??

1240


What is the main difference between ODS1 and ODS2 Hplc column.

5189


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2210


What is the accrptance criteria in RSD for RS method precision on basis of impurity percentages?

801


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

1997


why we should take dst factor for below 1%moisture samples

2647


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1794


if peak get problamatic then what require to do?

782


in which situation require to take incident in validation?

1711


what is the different in Total ash, sulphated ash, acid insoluble ash, alcoholic or non alcoholic ash?

9973


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

759