Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In UV we measure absorbance , how it is happend ? explain me

Answers were Sorted based on User's Feedback



In UV we measure absorbance , how it is happend ? explain me..

Answer / rajeev ranjan

IN UV there is "transition of electron".During transition Of electron from lower orbit to higher orbit it absorbs uv radiation following basic principle Beers Lambert law

Is This Answer Correct ?    24 Yes 1 No

In UV we measure absorbance , how it is happend ? explain me..

Answer / phani

Beers Lambert law

Is This Answer Correct ?    10 Yes 3 No

In UV we measure absorbance , how it is happend ? explain me..

Answer / durgaprasad

electron transision from ground stage to excited stage

Is This Answer Correct ?    4 Yes 0 No

In UV we measure absorbance , how it is happend ? explain me..

Answer / vilas

Uv radiation absorb by electron of specific sample.for excited stage they release energy . It causes absorption & trasmitance.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the difference between the Purity and Potency of drug substance

1 Answers   Divis Laboratories, Graviti Pharmaceuticals,


what is the value of pH

11 Answers   Reddy Labs,


why does used dry caffien in HPLC calibration?

0 Answers   Dishman,


How long we can use hygroscopic reference standard in terms of water absorb.I mean in line with respective monograph's specification or more than that?

1 Answers  


what is principal of karl ficher instrument!

12 Answers   Alkem Labs, USV,


who is the father modern liqiud chromatogrphy?

3 Answers   Amneal Pharmaceuticals, Car Chem, Cipla,


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

0 Answers  


which are the sizes of capsules?

0 Answers  


What is Spliit and Splitless in Gas Chromatography nad How does it work?

4 Answers   Sterling,


How to establish pKa for a new API molecule ?

2 Answers   Neuland, Sun Pharma,


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

0 Answers  


why we use caffeine for hplc calibration?

5 Answers   Aurobindo,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)