which Indian standerd code is used for billing

Answers were Sorted based on User's Feedback



which Indian standerd code is used for billing..

Answer / yuvarajan

IS 1200

Is This Answer Correct ?    70 Yes 2 No

which Indian standerd code is used for billing..

Answer / harinath sharma

There is no IS code not for billing, IS 1200 use for mode of
measurement.

Is This Answer Correct ?    45 Yes 4 No

which Indian standerd code is used for billing..

Answer / harikirangowda

IS 1200 use for method of mesurement only , for billing
purpose we have to refer BOQ for rate...

Is This Answer Correct ?    34 Yes 1 No

which Indian standerd code is used for billing..

Answer / dipen

IS 1200

Is This Answer Correct ?    17 Yes 2 No

Post New Answer

More Civil Engineering Interview Questions

Currently my house construction is going on but we just realized that the portico earth beam couldn't connect with the original earth because the beam rod not extended so Please advice

0 Answers  


how can i test sand on field in lebortry?.

4 Answers   ECCI,


What is the quantity of cement in mix m20 concrete?

0 Answers  


beam length 73 feet 4 inch,width 01 feet,height 50 inch so every beam load how much? and what quantity of M.S ROD? both side ony two column in middle no column.pls inform me that this is stable or not ? and how much risk of this beam?

0 Answers   Jindal,


RCC MEANS

7 Answers  






What is the Specific gravity of Fine and Coarse aggregate ?

1 Answers   Sohar Aluminium,


how many types of admixters are used for C.C. Road works

1 Answers   CADS Software, IVRCL, PSK,


what is the standard gradient or slope for drainage?

1 Answers   IGC, SPL,


Why was the empire state building made of steel?

0 Answers  


What is the allowable silt content for concrete works?

2 Answers   Sepco,


what is the minimum & maximum compressive strength n/mm2 of M-30 mix design cube

1 Answers  


1cracks found in brick wall in service building, how to rectify it,with low cost ? how to find propagation of cracks (in depthwise) and arrest on that stage? Is it require to design for Expansion joint in Brick work? if so what is the required distaces?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)