Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why potassium hydrogen pthalate is used for perchloric acid
And naoh. Why it is used for both acid and base

Answer Posted / sun

only one person knows ans
person name parshant kamalapurkar DGM QC polydrug

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

As per ICH related substances stability trend limit from initial to shelf life

3261


in api coa contains only process impurities and in product coa contains degradation impurities?

707


What is gelatinization?

1629


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2739


Many times I don't got a caffeine peak in calibration of hplc using guard column ❓

1826


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

2180


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1607


How to establish relative response factor for hplc. Why it is required?

1235


what is mean by covalidation

788


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3252


For titration in anhydrous media with perchloric acide, if lack of titrator, Which indicator is been used for replacement. How calculate pH of test solution to choose suitable indicator?

2320


Difference between the quantitative analysis and qualitative analysis?

1189


Why are use silicon oil mr?

1221


What is dose dumping? why require to do?

959


what is the purge flow & how to calculate

2656