Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


only one end point is possible for citric acid and we get 2
end points for di acid why?

Answers were Sorted based on User's Feedback



only one end point is possible for citric acid and we get 2 end points for di acid why?..

Answer / t.sengupta

at end point change in pH occurred due to different two pKa value. particular indicator has specific pH range.

Is This Answer Correct ?    7 Yes 1 No

only one end point is possible for citric acid and we get 2 end points for di acid why?..

Answer / balakrishnan

Actually Citric acid is having three COOH group, due to
this we should get three end point. This can be acheived by
using potentiometry titration(Measure the pH variation with
respect to Volume added). The pKa values are 3.15, 4.77 and
5.19. Each pKa contributes one end point.

Is This Answer Correct ?    0 Yes 0 No

only one end point is possible for citric acid and we get 2 end points for di acid why?..

Answer / guest

due to difference in chemical environment

Is This Answer Correct ?    5 Yes 9 No

Post New Answer

More Analytical Chemistry Interview Questions

how to hplc calibrated

4 Answers   Dr Reddys, Glochem,


In capadity factor formula is K'= (RT of main compound/RT of first eluted peak)-1 in this formula what is 1

1 Answers   Piramal Healthcare,


What is difference between Chromatographic purity and Related substances analysis?

3 Answers  


What is third generation HPLC Columns?

0 Answers   Emcure,


Why sodium lamp is used as source of Polarimeter?

12 Answers   College School Exams Tests, Hetero, NCL, Zydus Cadila,


How to calculate lamp energy in hplc?

1 Answers  


I have got selected for Aurobindo Pharma AR&D, HR person is asking me to sign in agreement. can I join?

19 Answers   Aurobindo,


what is Beer Lambert low ?

8 Answers   MAN,


what is the lamp used in SOR?

18 Answers   Aurobindo,


in determination of(acetone) moister content we are using methanol replaced by pyredine.what hapend in that reaction.

2 Answers   Glenmark, Neuland,


A ha tc is actual defination of retention time?

0 Answers  


IS THERE ANYWHERE MENTION THAT THE RE PROCESS BATCH REQUIRE TO KEPT STABILITY STYDY

2 Answers   Nakoda Chemicals,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)