Is there any other method of damping the oscillation in a
synchronous motor other than using damper winding and if yes
what is it?
Answers were Sorted based on User's Feedback
Answer / suryalok
yes there r two more methods to damp out oscilation they are
1----- u can use a fly eheel
2----- by using proper stiffness factor of the machine.
| Is This Answer Correct ? | 13 Yes | 2 No |
Answer / vijendra joglekar
Actually the main reasons for using damper winding in
synchronous motor for starting purpose i mean as we know
the syncronous motor is a inherently strting motor the
other method used for starting a synchronous motor is a
the rotor speeded up by another motor called a pony motor
to its synchronous or near syncronous speed then the
exciting current of motor s switched on the moment rotor
poles are excited ,they mechanically get interlocked with
the stator poles of opposite polarity.Rotor poles are
engaged with the stator poles and both run synchronously in
the sae direction.
Sorry guys the answer is too lenthy please read twice or
thrice in order to get understand..
| Is This Answer Correct ? | 2 Yes | 13 No |
what will happen if we use earthing inplace of neutral for domestic energy meter
5 Answers Polyplex Corporation Limited,
what is the difference between linear choke and suction choke?
Why electricity is generated and transmitted at the values of multiples of 11?
How can we find out earth leakage,(shock)in side the house?.. (with out ELCB)
11 KV distribution system where neutral is produced ?
4 Answers ciss, TATA, Tata Motors,
Why we have use 3 & 1/2 core cable use for general electrical supply arrangement
What is the purpose of stablization resistor in high impedance bus bar protection
what is a drive ?
tell me about xlpe cable?
1.what is electricity 2.what is electronice 3.how many modules 4.five electrical component with symbol 5.five electronice componene with symbol 6.how convert 220v.A/C to 24v/DC 7.220V.WAIRING DIAGRAM OF AMMETER/VOLTMETER/OHMMETEER
type of transformer
Why in India distribution transformer are connected in Dyn11 when we know capacity of v-v connection can be increased by adding only a single transformer?
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)