what is the cover used for footings, columns, beams ??? why
they differ & how they arrive??
Answers were Sorted based on User's Feedback
Answer / prakash
For Footing 50mm
Column 40mm
beam 25mm
slab 15mm
They arrieved as exposure condition.
Is This Answer Correct ? | 43 Yes | 4 No |
Answer / dinesh koli
Footing/raft side-75mm top & bottom-50mm
Colmn below gr.level-65mm
Column above gr.level-40mm
Plinth beam top, bottom, side-50mm
floor beam top-25mm, bottom-40mm, side beam>150mm-40mm beam <150mm-25mm
floor slab top & bottom-20mm
Is This Answer Correct ? | 4 Yes | 1 No |
Answer / sreenivas chitrala
For Footing 50mm
Column 40mm
Beam 20mm
Slab 15mm
Is This Answer Correct ? | 5 Yes | 3 No |
Answer / bala
According to Nominal cover as per IS 456:2000 The Exposure
condition matters,
For condition
Mild - 20mm
Moderate - 30mm
severe - 45mm
very severe- 50mm
& Extreme - 75mm
so for
Footing - 75mm
Column& Beam - 45mm
Is This Answer Correct ? | 10 Yes | 10 No |
what is period of de-shuttering for different area of slab of M25 grade?
How to calculate the cement, sand quantity for plastering? (10'x10')10mm thick ratio 1:5. wht"s the formula?
35 Answers Adarsh Developers, Amrapali, Ganesan Builders, MAHINDRA, NCC, Olympia Infratech, Omex, Ozone Group, Papni Associates, Perfect Arts, PPEC, Raj Construction, Ramky, Skyline Builders, VRR Builders & Developers,
purpose of binding wire in RCC. Structually is there any requirements that how to tie the binding wire like cross or single or how many pices combine together to bind the steel. i need structually importance of binding wire.
What is BOQ why to calculate BOQ
May I Get an E-mail ID or contact details of Mr. C.M.Dordi Vice President - Technical Sales Ambuja Cements Limited. Please
deshuttering time for RCC wall & column
briefly describe your ideal job?
what is mean by bulking of sand?
11 Answers CCCL, Kanakia Group,
Life of Rcc is taken as 100 years. What will be the life of structure after 10 years. will the strength of concrete increases or decreases.
How do I calculate the ground is resested for a 5 floor building?
can any one tell me in detail footing estimation .. i am new here in dubai so facing lots of problem...
0 Answers Golden Bridge Contracting,
One unit equal to how many brick
3 Answers Sainath Infrastructure,