what is the cover used for footings, columns, beams ??? why
they differ & how they arrive??

Answer Posted / bala

According to Nominal cover as per IS 456:2000 The Exposure
condition matters,
For condition
Mild - 20mm
Moderate - 30mm
severe - 45mm
very severe- 50mm
& Extreme - 75mm

so for
Footing - 75mm
Column& Beam - 45mm

Is This Answer Correct ?    10 Yes 10 No