what is the cover used for footings, columns, beams ??? why
they differ & how they arrive??
Answer Posted / dinesh koli
Footing/raft side-75mm top & bottom-50mm
Colmn below gr.level-65mm
Column above gr.level-40mm
Plinth beam top, bottom, side-50mm
floor beam top-25mm, bottom-40mm, side beam>150mm-40mm beam <150mm-25mm
floor slab top & bottom-20mm
| Is This Answer Correct ? | 4 Yes | 1 No |