what is a boiler tube leakage detector? ... what is the
working principle ?



what is a boiler tube leakage detector? ... what is the working principle ?..

Answer / sibapati

The sensors are mounted like soot blowers in a defined
space throught the furnance area.When a leakage occurs
(first being the pin hole leakage), the sound comes in a
definite frequency range. The sensors mounted detects only
this frequency and eleminates all other sounds being
produced inside furnance which are of differnt frequencies.
the signal then transmitted to RTU and from where it is fed
to DCS console. Note that you can only find the location
not the exact tube/coil no. Once you find the leakge
zone,secondary damages cen be avoided. Now this package is
included in all boliers from BHEL.

Is This Answer Correct ?    6 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

Technician A says the brake warning light is connected into both the parking and service brake systems. Technician B says the brake warning light will come ON only if the service brake system fails. Who is correct?

2 Answers  


What is an analog input-output

10 Answers   TN, Torrent Pharma,


Why humidity limit is 30 to 55 % for raw material storage?

2 Answers  


What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1 Answers   ADMA OPCO,


Can we get the outpot in c without using getch fiction? Answer is yes but output will stay on display 4 only few second.... But can we get output without using getch and also output will hold on the display...?

1 Answers  


What are the problems faced while testing HART instruments?

1 Answers   SSC,


plz... clarify my answer, how to calibrate vaccum (DP)leveltransmitter,it is hart. (digital).DETAILS:(coloumn)closedtank height 2650mm,and tx range is 0-1500mmH20.

2 Answers   KNPC,


Draw a 3 element level control loop and explain

1 Answers   CCIE,


HOw To Use 24V DC in Instrument?

2 Answers  


Why Differential pressure transmitter is located below the tappings points for steam & condensible vapor flow measurement application?

2 Answers  


Name and describe at least 4 status indicators, typically found on a PLC

2 Answers  


whats the reason for control valve not installed -90degree (down position)

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)