what is a boiler tube leakage detector? ... what is the
working principle ?
Answer Posted / sibapati
The sensors are mounted like soot blowers in a defined
space throught the furnance area.When a leakage occurs
(first being the pin hole leakage), the sound comes in a
definite frequency range. The sensors mounted detects only
this frequency and eleminates all other sounds being
produced inside furnance which are of differnt frequencies.
the signal then transmitted to RTU and from where it is fed
to DCS console. Note that you can only find the location
not the exact tube/coil no. Once you find the leakge
zone,secondary damages cen be avoided. Now this package is
included in all boliers from BHEL.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
Calibration of controller (pneumatic)
Which is the best field foundation bus. ( FF ) Yokogawa, Honeywell or others ?
What is the calibration procedure of Drum level transmitter if range is 0 to -400 mmh2o in lab?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
how to calibrate and troubleshooting of leveltroll?
Explain types of valves?
what diffrence b/w plc s7200,300,400
how many types of spped sensors n vibration sensors?their basic principle n connection?
how can i check vortex shedder bar it is ok? if there is ohms condition are shown correct?
what is your eligibility criteria for freashers?
Gas equation
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
What is zone,loop/fire alarm system?
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
centrifugal compressor interlock? Tell me the parameter at which compressor will trip