what is the weight of 8mm dia steel with 1 meter length.
Is there any formula to calculate the weight for any given
diameter
Answers were Sorted based on User's Feedback
Answer / s.mani
3.14*r2/h*density of steel (7.86ton/cum)=in grams
where,
r- radius
h- length of the bar
| Is This Answer Correct ? | 69 Yes | 30 No |
Answer / jayaraaj.arumugam
Weight of 8mm steel bar = 0.395 Kg/m.
the calculation is ,
0.8 * 0.8 * 0.62 = 0.3968 Kg/m.
| Is This Answer Correct ? | 40 Yes | 20 No |
Answer / v
One Meter Weight
Dia*Dia/162=one meter weight
8*8/162=.395kg
| Is This Answer Correct ? | 16 Yes | 3 No |
Answer / irfan kakar
dia*dia/162.162 =kg/m
note dia must be in mm NOW PUT THE VALUES AND TAKE A DISIRED RESULT
| Is This Answer Correct ? | 12 Yes | 2 No |
Answer / jekijanck
The formula for steel weight is : D^2/162*1=0.39506kg, where
D is diameter of steel.
| Is This Answer Correct ? | 10 Yes | 1 No |
Answer / g singh
Simple and easy method of caculating approx wt of steel
bars and easy to remember.
For Ex wt of 10 dia per meter:
Calculate accordingly ie 10 x 10 x .00617 = 617 say 620
grams per meter.
Like wise for any dia size Calculate Dia X Dia X.00617
say 16 dia = 16 x 16 x.00617 = 1.579 say 1.6 kgs per meter
and 20 dia = 20 x 20 x.00617 = 2.468 say 2.5 kgs per meter
Approx
| Is This Answer Correct ? | 5 Yes | 0 No |
Answer / k.paul lessley valavan
Rebar Weight Formula?
Exmaple:-
There is another way of calculating the specific weight (or unit weight) of a rebar. Especially for those who are interested of rebars less than 10mm of dia.
the way is to calculate it mathematically knowing that the
Note:-
a.] Density of steel rebars is 7851 Kg/m3.
b.] 8mm Diameter Rebar
A.] Formula:-
Unit weight [Kg/m] = Cross-Sectional Area [m2] x Density [kg/m3]
B.] Answer:-
Unit weight [Kg/m] = (22/7)x(radius)2 x 7851 kg/m3
Unit weight [Kg/m] = 3.14 x 16 x 7851 kg/m3
Unit weight = 0.395 Kg/m
8mm dia 1m weight = 0.395kg
Weight of Rebar = .0395[Kg/m] x Rebar length
8mm dia 3.66m length Rebar Weight ?
= .0395[Kg/m]x 3.66 [m]
= .14457[Kg]
| Is This Answer Correct ? | 6 Yes | 2 No |
Answer / vignesh k
the formuls is dxd/162
then 8*8/162=0.395kg/m
| Is This Answer Correct ? | 4 Yes | 0 No |
What is the strength of normal brick in india
what is curve ranging??
1 cubicmeter liquid = how much litre
what is mean by bulking of sand?
which tests for concrete pouring period at the site?
How much steel required for 1000 sq ft slab 4" thickness.
Does vetrified tiles needs to be cure before fixing?
What is plate load test?
Any body please let me know how to prepare Method Statement for Bored Cast in situ piles.
4 Answers Colliers International,
Why Vitrified tile are getting pop up.
I Have concrete mix with 440kg opc and having 37 mpa strengh in 7days while in 28 days only 42mpa can anybody tell me the reason for the same.
what is the name of shuttering oil used in oman
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)