Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Can we use thermocouple in generator of power station
replace RTD(pt 100)?
if we don't have any place for use RTD.

Answers were Sorted based on User's Feedback



Can we use thermocouple in generator of power station replace RTD(pt 100)? if we don't have ..

Answer / praveen kumar

ya posssible to use..even at the higher temp compare to rtd and thermocouple...thermocouple is best to use...while temperature cross above the range of rtd..its coefficent valve will change

Is This Answer Correct ?    0 Yes 0 No

Can we use thermocouple in generator of power station replace RTD(pt 100)? if we don't have ..

Answer / atif

yes we use the thermocouple on the power generator but
efficeincy is down.

Is This Answer Correct ?    0 Yes 3 No

Post New Answer

More Instrumentation Interview Questions

send me last 5 years questions asked in rrb chennai, for section engineer

0 Answers   RRB,


Define the terms Accuracy, precission, Spam, process tolerance while doing calibration of an instrument? Explaini with an example?

0 Answers   AquaTech,


why we are using digital signals for I/O & how to measure this signals is getting or not ?

0 Answers  


what will the sending unit in the fuel gauge utilizes?

0 Answers  


Hai friends I have dought for O2 analyser how to working in boiler area. And what is the basic principles

2 Answers   Enmas,


For an Instrumentation Engineer, is there any effect on Instruments of safety zones like zone0, zone1, zone2. As an instrumentation Engineer, what we have to consider or remember while working in these areas.( zones 0,1,2).

1 Answers  


IF PLC POWER FAILURE THEN WHAT HAPPEN?

2 Answers   IFFCO,


can u briefly explain aboutan aryton shunt multirange DC ammeter?

0 Answers  


what is solenoid valve?

6 Answers   Hindustan Zinc,


What is glanding

1 Answers  


in yokogawa prosef rd safety PLC how to data send frome local SCS to other SCS and other FCS

2 Answers  


Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)