Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


on which principle control valve works?

Answers were Sorted based on User's Feedback



on which principle control valve works?..

Answer / manoj

force balance

Is This Answer Correct ?    36 Yes 4 No

on which principle control valve works?..

Answer / anadi

following is the principle and statement==
Mechanical force due to actuator spring is overcome by
pneumatic force.

Is This Answer Correct ?    5 Yes 0 No

on which principle control valve works?..

Answer / k.ravi kumar

Force per unit area in the actuator

Is This Answer Correct ?    13 Yes 9 No

Post New Answer

More Instrumentation Interview Questions

hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.

0 Answers   Jindal,


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

0 Answers  


WHICH IS BEST INSTRUMENTATION OR ELECTRICAL ENGG?

3 Answers   SAS,


Dead weight tester & comparator for calibration , which is more accurate , what is the application.

1 Answers   Bapco Bahrain Petroleum Company,


Why thermo wells are used?

1 Answers  


NAME ANY TWO ELASTIC PRESURE SENSOR?

2 Answers   DVC,


State four different types of flow measurement.

4 Answers   ADMA OPCO,


what is the meaning of GK value(fullform) in flowmeter ?

3 Answers   Essar,


Why upper weighing limit of electronics balance is 90% of the total weighing capacity?

0 Answers   Emcure,


what effects a surging can produce in the compressor

0 Answers   Nemat,


What's the Installtion procedure of DP Transmitter for Gas,steam and water?

2 Answers  


i have a dp tx range is 5000mmwc. in which calibration i use in a open tank.1.5*3.5*2.5 mtr.for level msmnt. what is the calculation.

2 Answers   Bajaj Hindusthan,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)