Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

testing of Vector Group – YNaoD II

2987

When a single pase capacitor run motor- run on 230vac and Case(1)run with 8 Mfd 250 vac.capacitor , Case( 2) run with 8 Mfd 400vac capacitor. What is difference between both case regarding power ,efficiency etc?

2108

Dear Sirs, I am a technical persons.In one of our Electrical Sub- Station, We have installed three numbers of 1250KVA ,11KV/0.415KV Transformer to feed the Factory load. We have found some abnormality. In one of our Transformers the leakeage current from transformer body to earth through earth continuity wire is almost 86 Amp but in other transformer it is (5-10)Amp. where the load current on three phase and neutral are respectively 1360Amp,1400Amp,1370 Amp & 176Amp. So please any technical person help me about the reasons of this situation and how I can rectify the fault. Moreover,I have measured the earth resistance of the Earth continuity wire which is less than 1 Ohm. Thanks Tapas Barua

3 6026

What are the testing to be done before the installation of 1000 KVA Transformer?

L&T,

3 12023

What is Skin effect of the cable?

L&T,

8 14612

What is hysteresis losses?

GMR,

2 8319

What is third harmonic?what is the effect of it?

GMR,

2383

I've heard that most of the substations are rated in multiples of 1.11 because of form factor.What is form factor?

3 5579

How much pole motor can be desion for 415 volt ,50 hz.Power supply. in pratical condition . Prakash veer singh

5 8628

How can you test the vector group of power transformers?

2 6529

hi friends iam collecting details about motor,generator & transformer so send some web links to about motor,generator & transformer ,please help me .i need your help.thank u

4 6735

Can someone tell me how to calculate the size of a power cable? What are the factors involved in cable sizing?

5 8213

Could anyone clarify my wondering. What is the difference between knee point voltage and saturation voltage of the CT. Is their any formula to calculate these values?

2 6642

WHy neutral to ground trips when neutral touches the ground

1 4512

WHAT IS THE SHOPE TESTING

TATA,

2 5167


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What are the factors which influence the choice of specific magnetic and electric loadings of a synchronous machine?

2139


how is the magnetic current test is different in delta-star and delta delta transformer.

2243


What products have you designed which have entered high volume production?

2116


what is the reason for indication of light in the earth lamps of main switchboard.if there is an earth why does one lamp get dim and the other two bright.

2396


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1516


What is the meaning of loop in transformer

1858


what is relay what is protection & contact multiplying relays where it is used function in brief

1241


i am completed my degree(B.E EEE) 2014 anychance to get electrical licence plz help me

2204


If we need 4c× 50mm sq cable but it's not available so we can pull 4c×25mm sq two cables?

1464


what is dry and wet frequency withstand voltage? why & where it is used??

2497


WHAT IS THE MEANING OG (li = 7 In)

2260


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

3053


Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?

1265


Explain the fundamental difference between emf (electro motive force) and pd (potential difference) ?

1202


How to calculate Grid rotor resistance(GRR) losses in slip ring induction motor?

4330