Engineering AllOther (1379) What is the purpose of lighting Transformer used in Industries for Lighting illumination? Its necessary or not?
2 26835What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
1976Determine the minimum cable size for a 28A single phase final sub circuit originating from the distribution board supplied by three phase submain. The route length of the final sub circuit is 54 m. Assume 1% voltage drop in the consumer's mains. Submain specification: Cable: 50mm2 4 core V75 copper; Route length 42m; Maximum demand 135A per phase
1 5440why we provide bent up reinforcement bars at l/4 ? if it is because of diagonal shear , how does it acts ?
3035
what is gas metering system? gas chromatograph? and gas compressors?
In control room of our one plant there is a continuously the incoming power goes to PC is vary,means in stabilizer it continuously indicate from high input to low and low input to high. what is the reason and its solution.
From reading, Under voltage relay used also as phase sequence relay now, Why I use under voltage and phase sequence relay in the same circuit (ATS)?
Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
What are the classifications of heating element?
which transform is better? haar or hadamard
Repected sir/Madam, I am goingb to face IOCL technical as well as HR interview, can you forward your hellpfull hand for toward me to sort out my problem by giving some imp interview quetion which is generally asked in chemical industries such like IOCL,HPCL,ONGC,BPCL,RIL,etc I will always thankfull to you,for sharing your profficient knowledge with me and making me somewhat technically sound
Define demand factor?
what are the cube & Sylinder strength of concret M20,M25,M30,M35,M40,M60 ,M75,M10 ,M15
sir am giving jspl exam on 19th oct . i belong to eee, so plz send previous question papers ..........to dis id abhilash203@gmail.com
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com
Is single load(eg: three phase motor) having all the components like positive,negative,zero sequence components during fault condition?
what is relay what is protection & contact multiplying relays where it is used function in brief