Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

In CDMA we are use PN'pseudo random noise ",why is is call Noise.

TATA,

2 7782

IN 3 phase induction motor where we give i/p supply & how its working ?

2 4519

How many number of bricks required for 1 cum & how much mortar quantity require for 1 cum

Assurance, Campus Interview, R Tech Developers, Ramdev Construction, Synergy,

22 117829

Laboratory experiments conducted in Mumbai on a particular mix showed a strength of 33 MP a for a fully matured concrete. Find whether formworm can be removed for an identical concrete placed at Jammu at the age of 15 days when the average temperature is 60C. The stripping stress in concrete

CCIL,

2 5167

how we calculate the motor rating of pump for water suction ?its any formula for that plz give thank u

3 8391

Why 24VDC power Supply is used as standard for all loop powered transmitters?

Lupin,

8 28176

on what factor insulation resistance depends

Uttam Sugar,

2 9421

explain how to protect high rise building from the risk of lighting.

1 2422

State uses of different types of stsrters with different capacities of motors as below: a. up to 5HP b. above 5hp to 10hp c. above 10hp to 20hp d. above 20hp

2084

What is power factor? How to improve Power factor? draw a circuit diagram showing the connection of power factor improvement equipment to the electrical instillation.

1 3066

A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram

2816

what is load balancing. what maximum load diffence is allowed between phases.

1 4546

-What shall be short circuit current of LV switchgear for a 1000 kva, 11.415kv, 3 phase tranformer with 5% reactance.

2132

-How do you select cable size for a given load at a given distance from source of supply. How do you find voltage drop.

1798

-What should be minimum value of insulation resistance and maximum value of earth resistance at any electrical instillation and what is method of testing the same.

2100


Un-Answered Questions { Engineering }

What are segregation and bleeding?

1194


Explain the main advantages of synchronous circuit?

1011


PLEASE ANY ONE READ THIS MESSAGE ANSWER ME AT MY EMAIL ID surendrasaroj18@gmail.com sir i am prepairing for section engineer exam taken by railway my branch is chemical engineering i want previous paper of chemical engineering of section engineer exam taken by railway. please answer me as soon as possible thankyou

2104


what do you expect from this company?

2246


my dear friends i want to know about pattern of HPCL & SAIL written exam papers. so please send me the details.

2052


what is the service corridor?

2387


What is sae?

1094


What is the practical way to calculate the cable size for known ampere load?

1435


Determine the BTU size of an aircon for 20 sq metre room

1878


what is the role of transistor in Circuit?

1189


What is the requirement for over all CG of DG from the foundation surface to absorb the vibration of heavy set.

2079


What is the difference between vector surge relay (78) and Pole slip relay (98G)

1207


What are the internal and external faults?

1109


how many joints are allowed in underground HT cable of 1 KM

1878


Y phase plates are used in transmission line??? what is there need???

2922