Engineering AllOther (1379) How we calculate the recovery of steam as per coal in a boiler if we know the calorific value of coal?
1816We have ONLINE UPS 15KvA (3PHASE 440V I/P,3PHASE O/P,440V) I want to step down from 440 to 220 V What to do. Pl. suggest with specification.
ARDE,
1 3244what should be sensor sensitivity of accelerometer in vibration? And what is the main difference between accelerometer and proximity sensors and others?
2506an ac induction motor gets overheated when operated at a low frequency of 25 hz a instead of 50 hz. reason?
1 3843Sitrans LR460 Radar level transmitter getting level out or disturbed level during moisture present in the material ie coal in the pccb bunker in CHP.Any suggestions for this problem...????
1 4601can we use ps class in combination with protection class in differential protection and over current protection.
1 2839
explain bug tracking system in detail.
Explain the types of sensors.
in the construction of residential building what type of tank are used?where?why & what is its purpose?
Define Workability ?
sir/madam, i've applied for the post of section engineer. i shall highly be obliged if you could help me out with some sample papers.
how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)
what is the AC Plant and how can do the work with parts and picture tell us 150 Tr
which power station plants r more efficient? which is less? which is most expensive and which is cheapest?
When to use Stub and Not So Stubby Area? 10. How to get the external routes without making area Not So Stubby?
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
how much percent are used 20mm,10mm?
what is purpose of use stug.
what are thyristor family and explain it?
How many battery discharges?
What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?