Why the standard of ambient teperature mentioned as 40 degree celcius in machines.

1457

what is the full form of embedded system

2 11593

How can calculate rotor temperature of the alternator? and is there any method to calculate that

1 3507

How to calculate Cement, Sand and Kapachi required for M20, M25

NCC,

3 10173

what should be the motor rating for pumping water for house hold use from 60km far lake and what formula is to use please tell me

1 1890

Why should The rating of 11 kV DO Fuse is in mulyiple of hundred(200 Amp. 40 Amp, etc) Ampere wheareses the its fuse elemnt has rating in just few Amp (< 12 Amp)? ( Is it jusy beacuse of factor of safty).

1 3632

1.what is surge 2.what is lightning 3.what is switching 4.difference between surge,lightning,switching used in power system 4.definition of surgearrestor,lightningarrestor 5.adv and disadv of surgearrestor,lightningarrestor 6.uses and purpose of surgearrestorand lightning arrestor 7.block dia of surge arrestor 8.blockdiagram of lightning arrestor 9.operation and working of surge arrestor and lightning arrestor 10.basic formula of surgearrestor and lightning arrestor 11.basic diagram of surge arrestor and lightning arrestor

Crompton Greaves, Framo, L&T,

1 5596

why we increase the small speed of turbine when alternator just synchronized to grid in steam power plant

PSEB,

2 4485

In 120 m high RCC Chimney shell construction how we can calculate the inner and outer dia of shell at every +1 m level as this shell is inclined from bottom to top.

4 13834

how many area req.in 15000liter water tank

7 11548

it very simple A is a father of B..... B is not son of A.... what's the relation b/w A&B????

2 3307

can we resonance with triple bonds?

1637

composition of cast iron fc-500,fc-550,& fc-260 which is use in sheet metal industries as a piller set

2994

How to calculate cement required for m20,m5 grade

MSEB,

8 51262

What is cement-concrete ratio ?

4 8206


Un-Answered Questions { Engineering }

what are the differences between dcs & plc & scada?

572


What is the best way to control an oversized, horizontally oriented shell and tube steam heater?

645


Types of (Open Shortest Path First) Link State Advertisements (LSAs)?

1665


How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?

2021


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

1516






why not overloading -,=,_,\ operator

1489


State the laws of thermodynamics and its importance of in mechanical engineering.

603


column at edge of a framed structure is uniaxial or biaxial. and is an interior column is biaxial

3495


how to remover corona effect and hysteresis losses from contactor

1570


Tell me what is all over design?

1


What are the operation carried out in thermal power station?

635


what is the solution for meger test failed the MV cable?

3541


Derive the expressions for average output voltage and rms output voltage of 1φ semi converter?

617


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1457


discuss the technique for implementing high performance computing

1043