Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Power Plant Engineering Interview Questions
Questions Answers Views Company eMail

What are the motors used in a thermal power plant? (With type and ht/lt) What voltage levels are used in a thermal power plant?

OPG,

2 15838

what is the meaning of SST300 V56A in SIEMENS turbine

Siemens,

4301

thermal power plants in steam using inlet of turbine.inlet of turbine pressure and flow is same as boiler feedpump why not use direct to turbine?

IBPIL, JSW,

6 13419

What will happen if id fan on boiler not functioning?.Can the Boiler run without id fan? What is the effect?

4 15761

dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job

dbpl,

2488

what is scanner air fan & how dose it work & is there any interlock in power plant

APGenco,

3 36456

During shutdown of Steam Turbine,How do we cross the critical speed?

OPG, Power,

7 18659

If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakage. Then it's motor current get affected or not??

1 3874

I want to build 100 megawatt hydel dam. What does mean, 100 MW per hour? then how many electric bulb of 100 Watts the dam would lit?

1 6776

What is df/dt protection?, How to calculate setting range of 30 MW steam generator???

DS Sugars, MEMF,

1 11758

what is the relation between the grid voltage and generator voltage how to link up generator with grid

NDFL,

3 8201

Need of oxygen dosing in super critical powerplants?

5 11569

63.5 ohm NGR is connected with our gas engine genrator running at 500 rpm, 50 hz and synched with WAPDA at 6.3 KV bus voltages, 2500A and 25KA(1 sec). can some one give me proper calculations how it comes 63.5ohm?????

UET,

2 5212

some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

UMT,

2347

what is the real reason than natural draught cooling towers are always in hyperbolic shape

2 8661


Post New Power Plant Engineering Questions

Un-Answered Questions { Power Plant Engineering }

LAPT working in alternator / generator

3557


By any way can we increase the B check hours from 300 to 500

2142


what is the meaning of SST300 V56A in SIEMENS turbine

4301


some one can tell me how residual type excitation is provided through transformers to an AC generator without any battery or PMG&excitor

2347


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

2412


what does mean by kva rating

1440


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

943


why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.

3181


can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525

1688


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1644


Why superheated are started before I'd and rd fan?

2118


What is LB-SR.

2951


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1652


How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.

2237


explain how the third harmonic content of the magnetising current affects transformer design

3205