Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


If a pump has "N" no .of conections in the discharge. If a
connection has a heavy leakage. Then it's motor current get
affected or not??



If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakag..

Answer / anbu

Heavy leak
There is no way to maintain the required pressure so its better to stop the pump, otherwise power waste.

Light leak
If your pump running with VFD ( variable frequency device ) or scoop adjustments, then you can able to change your pump speed. If you increased means pressure and flow also increased at same time amps and power also increased.

Is This Answer Correct ?    3 Yes 0 No

Post New Answer

More Power Plant Engineering Interview Questions

What is the use of Hydraulic Coupling in-between BFP pump & BFP Motor?

1 Answers   Lanco, XYZ,


If a pump has "N" no .of conections in the discharge. If a connection has a heavy leakage. Then it's motor current get affected or not??

1 Answers  


what is absolute separator, how it works, what are the types in it

1 Answers  


if suppose boiler has high heavy tube leakage, so in which time we feed the water in a boiler. can we stop the feed water at particular combustion temperature.

4 Answers  


63.5 ohm NGR is connected with our gas engine genrator running at 500 rpm, 50 hz and synched with WAPDA at 6.3 KV bus voltages, 2500A and 25KA(1 sec). can some one give me proper calculations how it comes 63.5ohm?????

2 Answers   UET,


What are the special criteria under which FD fans are switched off during MFT.

1 Answers  


What happens if there is no HP and LP By-pass.

5 Answers  


Why reheater is not used after IP turbine.

3 Answers   Hindalco, SEC,


why Subcritical has 60% condenser capacity

1 Answers  


What happen when the AVR of the generator fails? Will it cause power instability and total failure of the alternator?

8 Answers  


.What is drip and drain.

2 Answers   NPTI,


What happens if air is present in LPH and HPH.

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)