what is scanner air fan & how dose it work & is there any
interlock in power plant
Answers were Sorted based on User's Feedback
Answer / bnbnbnb
Scanner air fans are small fans ( Both AC & DC) for supplying cooling air to scanner head.
Scanner heads are placed near the fuel nozzle of every elevation to monitor the fireball of the furnace.
Is This Answer Correct ? | 35 Yes | 2 No |
Answer / sunny sharma
Scanner air fans are small fans ( Both AC & DC) for supplying cooling air to scanner head.
Scanner heads are placed near the fuel nozzle of every elevation to monitor the fireball of the furnace. Taking suction from FD fan if fd fan trip than it will take suction from atmosphere air
Is This Answer Correct ? | 21 Yes | 1 No |
Answer / brajesh_genus
nothing but to remove flame scanner lance dust & taking
suction from atmosfier air and purging to lance & no interlock.
Is This Answer Correct ? | 6 Yes | 11 No |
What is the over speed in turbine? What is critical speed?
what is the difference between flow and force ,draught and vaccum ,tube and pipe?
why airtel use + 24 volts and other operators use -48 volt
0 Answers ABC, Airtel, INDUS, Reliance,
I am opertaing generators which are beyond 14000hrs and now the fuel consumption is about 2kw per liter of diesel. The engines are due for overhauling. is this normal
2. what is meant by exhausthood temp?
.What is drip and drain.
why seal air fan is used and where it is used and where is suction taken from
What is droop.
2 Answers Dhampur Sugar Mills, Elaf,
what is the trip circuit supervision in an electrical meaning?
What happens if air is present in LPH and HPH.
What is precaution and after implication for 100% pet coke firing in AFBC Boilers?
what is the real reason than natural draught cooling towers are always in hyperbolic shape