Chemistry Interview Questions
Questions Answers Views Company eMail

which element is good conductor of electricity but bad conductor of heat

L&T, UPSC,

4 11699

For Recent draft guidelines for Dissolution test apparatus calibration, why removing the salicylate tables?

Alkem Labs,

3 9168

How can v calibrate ftir ? Plz explain me

Cipla,

2 17766

what is the diff betwen calibration and system suitability?

8 19576

Why Methanol used in KF Titration?

Glenmark, Lupin,

15 63692

Why do we use 500ppb sucrose and 500ppb 1,4 benzoquinone in TOC calibration?

Vardhman,

2 8110

what acid present in milk

17 16016

pls send me the solved paper of health & malaria inspector to santoshmaurya.087@radiffmail.com

RRB, TCS,

2456

why chiral separation?

1 7791

what is main use of primary standards in caliration

Lee Pharma, Lupin, Nectar Lifesciences,

2 5314

what are the important specifications for a Column ?

2 9031

why xylene use in saturated polyester resin

1 5875

why are take potassium hydroxide molecular weight in total amine calculation

1 3728

What is kentchin? Is it real? As much info on it as possible.

2 5759

what is the purpose of Buffer in any titration?Ex:In determination of hardness of water we use ammonia ammoniachloride buffer in titration with EDTA.Why?

Amity, Prakriti, Sr Comunications,

13 87474


Un-Answered Questions { Chemistry }

chlorination of methane is possible and a mixture of products are obtained. Is flourination and Bromination of methane is possible?

1624


why salisylic acid not using now days for disdolution calibration?

309


How to synthesize methylene bisthiocyanate using CH2Cl2 and NaSCN?

2448


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1121


Which is the highly polar and highly non polar column in HPLC?

1790






In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

2965


What are filters? Why are they used?

605


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

1308


why in uv calibration in Limt of absorbance parameter specific absorbance is calculated only for selected wavelength

2205


What is the requirement to give RFlow when using RID detector?

2598


What is column in chromatography?

1767


Define dipole moment?

605


Comosition of bell metal

1311


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2112


how to calibrate hplc & gc

4037