Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

hello dear i have faced problem in drum level transmitter. the problem is when i engrize the meter meter shows 100% but the actual level 40 or something plz suggest me

7 9632

Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1887

Name four general (not technical) criteria that would you consider important, when deciding upon a particular control valve?

1 3945

Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

2211

i install a DP transmitter of Faugi on drum level of boiler but i face a problem in it when i engergize the transmitter the meter shows 0 or 100% no variation in it.the distance of two points is 19.5 inches, i am in trouble please suggest me what can i do it's very urgent Please reply me as soon as possible Best regards ikraam haider

5 8066

what is the difference between plc & DCS?

Cheminova, NGIL, Siemens,

5 9475

why we use npn sensor in vibration monitoring system

1 3015

why we use sensing type(NPN)on a vibration monitring system not a (PNP)sensing type

1 3290

what is the diffrence between LCN and UCN

2 21139

What is the function of SMPS

2 7730

when we are using HART COMMUNICATOR why we are using 250 ohm resistance while using HART COMMUNICATOR.

7 18913

what is moisture probe? What are there types? What is there working principle and how they works? guys this is one of technical question I had ask in interview. If you know its answer please let me know. The interviewers were more interested in microwave moisture probe, so if you find its any link please just forward me on my mail id.avinash1200@gmail.com Thanks in advance.

2042

What is the main difference between Cavitation and Flashing?

1 14342

Why we used cage in control valve?

8 10892

A pressure Tx accuracy is 0.2%. Signal o/p is 4-20ma.span is 16 Ma.how many deviate the o/p then calibration needed

1 3864


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

can anyone tell me about the basic concepts to consider before to start a PLC panel wiring

1935


how to calibrate Necleuonic level transmitter.?

2108


How digital input and digital output 's are working in dcs

2546


how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw

2656


Specify for Cables - Flame Retardant and Fire Resistant?

2045


What you mean by multi stage control vavles?

1811


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2174


Describe a time when you anticipated potential problems and developed preventive measures.

2914


What is Droop? What is Step/Gradient Limiter in Turbine Governor control?

3402


how to work static pressure sensore how to work dpt

1873


which type of zones used for boiler? & why ?

1865


explain key exchanges in all security modes WPA,WPA2,TLS?

2046


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2266


what is cems analyzer explain with principle and drawing ?

2381


What are the types of control valves available

2108