State 5 different method of level measurements.

SRACO,

3 5978

what is the essential difference between DIODE and SCR in term of application.

ADMA OPCO,

2 5082

In turbine, what does term CDP, NI, NH, HSSOC, means

ADMA OPCO,

2322

An equipment is certified for EEX, IA, IIC, T6, what do you under stand by this.

ADMA OPCO,

3 6814

I HAVE PRESSURE TRANSMITTER WITH TWO WIRES 24 VOLTS SUPPLY.IF TRANSMITTER WILL GIVE SIGNAL TO THE DCS WHAT HAPPEN TO THE 24 VOLTS POWER SUPPLY IT WILL DROP OR REMAIN TO 24 VOLTS POWER SUPPLY.

3 6890

what is sequence table in DCS . make a logic in sequence table for tripping of ID fan in Boiler(in YOKOGAWA CS 3000 DCS).

Yokogawa,

1 6879

Dear all... I have 1 0-400 duplex type RTD, I connected the A side to the temperature indicator and B side to the PLC panel, but when I have observed then found that The PLC side temp has the variation. and it was distub to other RTD temp also. so what can I do.

1 3950

Dear all... I have 1 0-400 duplex type RTD, I connected the A side to the temperature indicator and B side to the PLC panel, but when I have observed then found that The PLC side temp has the variation. and it was distub to other RTD temp also. so what can I do.pls help me

Worley Parsons,

1 4480

Can we used Condensate Pot on flow transmitter which is using on liquid having sluge and DP transmitter is in pit and below the process line,Can we used Condensate pot for accamulate the Sluge?

1 5131

What properties or parameters to be taken into consideration for protection while selection of Dcs controller.

JPL,

1 3720

What is the difference between ROM & RAM .

Sabic, SPIC,

1 4809

Can we use a 10000 Lph Flow Transmitter in 100 LPH flow line to get 20mA O/P by adjusting SPAN ?

1 4222

in differential pressure transmitter,min&max pressure range for hp&lp

1671

What is the difference between EPROM & EEPROM.

Sabic,

1 8607

What is scale factor of proximitor & unit of the viabration.

Sabic,

2 5399


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Who to difference between analog in & analog out in dcs?

1165


In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.

2620


Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?

851


Hi i m B.E. In elect. & comm. I m workin in bio mass plant from 6 mnths as inst. Engg. but now i m in dept. Of operation as shift engg...which is best operation or inst. 4 me? M confusd..plz help and reply me..

3573


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2420






Draw bode plot of any transfer function. Why is plotting bode necessary?

2112


Isometric drawings are generated during _________________ phase of a project

1743


Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

1873


control panel design guidelines

2984


Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows

1796


what is your eligibility criteria for freashers?

1756


plz send me general of ongc

1666


What are different types of control valves?

1028


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1850


When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.

1513