How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
630Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
1978how will you segregate the alarm levels in alarm management system during factory Acceptance Test
1902Post New Instrumentation Questions
what are the values of fuel flow rate in various places in boiler.
What is the difference between PLC and DDC?
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
How to calibrate smoke Dectector
what is gas metering system? gas chromatograph? and gas compressors?
what is the responsibility of an instrument commissioning supervisor
Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd
key phaser where is use and work
sir ,iam in dem urgent need of HPCL Paper of Instrumentation Branch plz send me at your earliest convenience at ujjwal_sharma1983@yahoo.com
Where is wet leg is used?
Explain the combusion chamber
What is sensitivity in vibration probes..?
a flow transmitter [range-0-400mbar] connected in process line. please explain me how to calibrate the flow transmitter , & how to do static error