How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
1302Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
2409how will you segregate the alarm levels in alarm management system during factory Acceptance Test
2318Post New Instrumentation Questions
what is the electrical operation procedure for switching on 27.6MVA electric furnace.
Programmable Logic control.
what is the minimum power (P=VI)to produce a spark?
Sir, I want junior executive, Instrumentation question papaer for IOCL, Plz send to arabinda.ghosh83@gmail.com
how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr
Capacitance, resistance ( colour coding ), parallel & series circuits.
What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?
how u choose thermowell lenght n pnumatic C/v size?
Definition of reverse and acting controllers:
what is the difference between profibus and controlnet networking.
we have a s-5 simense plc having op7 .recently on op7 showing error 1.plc not present 2. DB error frequently. can u have any solution . please send me.
what would be the minimum flow rate that we can measure on rotameter..?
How works weighfeeders in cement industry? what is the working principle?
How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)
How to erection of DCS Panel at site step by step