How do you identify between actual alarm and false alarm in a Temperature Transmitter in SCADA based Control System
1317Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (
how will you check torque value during Factory acceptance Test for control valve/ESD ON/OFF VALE how will you confirm this torque value is being correct, Which document will you be refer.
2427how will you segregate the alarm levels in alarm management system during factory Acceptance Test
2339Post New Instrumentation Questions
Q-Explain the different load conditions that will produced different offset which may or may not be acceptable to thhe control function
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......
What is zone,loop/fire alarm system?
hye SAM acn u send your e mail id, so that i can solve my query through e mail?
where proximity sensor installed on tank in loading arm application
How many interlocks at turbine side?
what is actual drum level and compensated drum level?
What is the exact differences between HART,FOUNDATION FIELDBUS,PROFIBUS?
what is sil (safety integrity level
How to Calibrate Level Troll in field
Why all the drains(Gland sealing,ESV,Casing inlet etc) are directly connected to the flash tank instead of hotwell of the condensor in the power plant? My Email Id:naba02222@gmail.com
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
What is eddy current? Describe the operating principle of proximity probe.
what different types of problems do occur while doing instrumentation commisioning and how to solve them? please explain in detail