What are primary elements of measuring pressure? Which type of pressure can be measured by these elements?
734Using your own examples solve a problem involving normal table. (experimental method and analysis)
774What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?
844Post New Instrumentation Questions
Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com
please tell no. & add. of consultancy who recruit me in power plant as instrumen engg. present i m working in power plant as ass.t instrument engg. thanku mahesh 09226562826
Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.
Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?
Calibration procedure for Electro magnetic Flow meter
If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?
How to Calibrate Temperature Switch in field
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
What is modbus?
How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?