Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

PID controller is used for which type of compensation…… a) lead comp. b) lag com. c) lead lag com.

Engineers India Limited,

12 23988

Induction type 1-p wattmeter reads ….. a) true value b) apparent value c)volt ampere value

Engineers India Limited,

3 8699

How much voltage we get between two wire of 4 to 20 ma output? Is this voltage up or down respectvice to 4 - 20 ma ?

9 14784

which type signal come control valve

6 10914

which type signal in & out in dcs

4 15815

Why we use 250 ohm resistor in series with HART protocol communication?

Chemtrols, Instec, Sabic,

13 58816

I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1951

1.what is the role of proportional comtroller in pid controller?2.How do u calibrate the control valve?

Bently, IOCL,

3 11368

Why only negative 24 vdc supply give in vibration measuring system.

6 17886

why 1 to 5 vdc is used for output measurment

4 9433

if we have 380 KVA DG. how to calculate Power Factor. With detailed formula

1 6463

How to calibrate the magnetic flow meter and how to correct the flow if it is showing more flow.

Bohra Industries Limited, TCL,

5 28211

In electronic board one fuse(rating 230v,100ma)showing 2.5 ohms with multimeter,then the fuse is healthy or not.

4 7799

Which softwere is required to communicate the S7-300 processor

4 8661

What is the difference bitween control net scaner and device net scaner

Binani,

3639


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

How to convert milliampares into flow??

1777


plz tell me clearly about PID.."when v have to change I value,D value,GAIN??

2242


for oil & gas industries which zone is normally preferred? why? give its example?

2054


Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz

2104


what is the input of digital counter during the the calibration time?

2380


Explain pH, Conductivity.

2212


What is the start up procedure of desalter

3743


detail of mass flow meter pricipal

2361


Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com

3267


selection of the zener barrier for the hazardeous area zone 0

2313


How to work togather like sov,limit switch,proxy switch and booster in xv

4296


Why the ammonia and Nitric Acid level indicators is with millimeter ? and What is the conversion form millimeters that level indicator indicate to weight ?

1921


Derive capacitance to 4-20ma conversion formula / relation in capacitance type pressure sensor?

2300


Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?

1829


Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.

2070