Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

Explain " FAIL SAFE " feature in temp. measurement.

Bapco Bahrain Petroleum Company,

1 5307

What is meant by cold float of compressor shaft.

Sabic,

1 5135

What is offset in a control system.

Sabic,

2 9005

What is the relationship between GAIN and PROPORTIONAL BAND.

Kharafi National, Sabic,

1 8088

What is the purpose of valve positioner. Explain 4 uses.

SRACO,

2 7507

What is cavitation. what is the effect of it on control valve and how is it prevented.

ADMA OPCO,

1 5314

What is meant by GAP VOLTAGE, in vibration measurement. Normally how much GAP VOLTAGE is set and state the reason.

ADMA OPCO,

3 31063

What is surge and how is it prevented.

ADMA OPCO,

1 3413

What is the purpose of bypass valve across AS valve.

ADMA OPCO,

2102

State four different types of flow measurement.

ADMA OPCO,

4 9053

Give 2 application of quartz crystal used for process parameter measurement.

ADMA OPCO,

1 2981

What will the new flow factor if D/P Transmitter is RE-RANGED from 25" WC to 50" WC

ADMA OPCO,

3 10560

What is the out put of pressure switch & electronic pressure transmitter.

ADMA OPCO, Al-Barrak,

5 8938

can any send me a forbes marshall dtron 316 manual

1956

Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

2215


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

what is compensation? temprature & pressure

2011


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2189


What is the Working principle of Dozing valve?

2201


I have energy meter for educational project having 0.5s class but my friend need 0.2s class meter , which one is good for that purpose and what is the actual difference of that two classes , need very easy example also.??

1404


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

4012


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2450


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1890


anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me

6030


Explain Gas Turbine startup and shutdown sequences

4319


hi! i want to know about mpse exam.

2289


How to calibrate level transmitter with use of HART?

2758


If we increase only P what will be controller action ?

2467


What you mean by multi stage control vavles?

1810


what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .

4846


Positioner usage.

1931