Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.

TNPL,

3016

what are the steps to commissioning a DCS system?

BGR Energy,

2 16734

what is orifice plate? Give me best answer?....plz

5 11383

Can we use twisted pair cable instead of ethernet for communication?

Yokogawa,

1 8052

How does a redundant controller comes in line when the main controller fails??

Yokogawa,

3 9599

DCS marshilling Cabinet Power supply can be replace during plant running time?

1 5039

Why do we use 24V DC supply in instrumentation? What are its merits and demerits??

JSW, MJPRU,

1 9681

CAN WE CALIBRATE LEVEL TRANSMITTER USING HART COMMUNICATOR WHEN WATER LEVEL IS PRESENT IN THE BOILER SHELL?

Chemin, Emerson,

4 10935

pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.

Siemens,

3125

what is compensation in engineering and what is temperature compensation?

Binani, Yokogawa,

1 5647

1.what is controller proportional gain 2.what is the controller intergral action time. 3.A proportional plus derivative controller that has a proportional band of 20% and a derivative action time of 0.1 minutes. Construct the shape of the output waveform for the triangular input if the input rises and falls at the rate of 4 units per minute.

2684

I have a Control VAlve having size of 2 ".Only the known parameter is Pressure drop . Its 2 Kg. Then How to calculate control valve sizing means Cv.

JSW,

2353

what is the Difference Between Domain and Station?

Emerson,

3 10874

how to calculate density?

2 6057

How to check vortex flow meter is in good condition while we do not having calibration setup?

4 8984


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.

2026


Explain how thw analog to digital converter works with the circuit diagram

2671


how to do dynolab wind speed sensor loop test, how to simulate value,i have simulate mA 4-20mA but not responding in DCS faceplate, please kindly advice me any one.

1046


what is instrument philosophy

2264


please someone tell me what is function of vibration sencer and how many types and how to control viberation.please. my id is jimmykhan077@gmail.com

1833


What is profibus?

1122


I want to buy a seal kit of a pneumatic power cylinder.But I don't know it's specification.So please help me to know its specification.

1943


Q- What are the application in which PNP transistor is preferred over NPN ?

3344


the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

2079


I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?

2208


What is instrumentation measurement?

1113


sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.

2465


can we create an interrupt in plc through scada?

2377


how to calculate signal cable sizing? and multipair cable sizing??explain in brief?

2353


we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.

2064