how cubic feet cement,sand,aggregate required for 1 cubic feet
ratio=1,1.5,3
Answers were Sorted based on User's Feedback
Answer / mohammed aijaz hussain
Volume of concrete = 1 cu.ft.
Volume of Dry concrete = 1.5 X 1 = 1.5 cu.ft.
Volume of cement required = 1/ 5.5 X 1.5 = 0.273 cu.ft.
= 0.22 Bag = 11 kg.
Volume of sand required = 1.5/5.5 X 1.5 = 0.41 cu.ft.
Volume of aggregate = 3/5.5 X 1.5 = 0.82 cu.ft.
Is This Answer Correct ? | 19 Yes | 8 No |
Answer / ratheesh
cement = 7.5 kg
sand = .0076 m3
Aggrigate = .015 m3
Is This Answer Correct ? | 16 Yes | 9 No |
Answer / bharathi
cement - 8.22 Kg
Sand - 0.428 m3
20mm BM- 0.856 m3
Is This Answer Correct ? | 4 Yes | 1 No |
Answer / arunkumar
cement = 3 kg
sand = 0.75 band
20mm metal =1 band
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / darshandachchu@gmail.com
cement=403.5kg
fa=.42cum
ca=.84 cum
Is This Answer Correct ? | 2 Yes | 2 No |
Answer / r.suresh
cement= 11kg
sand = .012cuft
aggregate=.024cuft
Is This Answer Correct ? | 9 Yes | 11 No |
Answer / n.rajeev
sand = .012cft
coarse aggregate = .024cft
cement = 17.28 kg
Is This Answer Correct ? | 6 Yes | 8 No |
Answer / v.purushotham
Coarse aggregate: 0.96 cu.ft
sand : 0.48 cu.ft
Cement : 13.06 cu.ft
Is This Answer Correct ? | 1 Yes | 3 No |
What is a tensile strength? What is the tensile strength of wood?
use 1:1.5:3 concrete footing size 9'9" *9'9" and square 12" and also trapezoidal 22" use of 4 columns. calculate how much amount f concrete use. and also tell me the details about course aggregate and fine aggregate and cement bags use .(note; 20mm coures aggregate use)
what is the unit for sbc of soil
what is the comprasive stranth of brick
five requirements of infill panels for walls?
can u plz send me ntpc placement papers(civil engineering) at munjalricha1988@gmail.com and which types of questions are aked by ntpc
How to check Diameter of Np2 rcc pipe?
mean of NH4 pipe
Method for Calculating the WEIGHT OF ANGLE ?
What is the diff. Between rectangle & parallelogram?
how to calculate steel for beam of simple home and for heavy buliding ? explain me briefly
why 50% more is assumed while calculating dry volume of coarse and fine aggregates in concrete calculations.whether 50% more is correct? How is it decided? whether the same is applicable to cement volume. Also what about cement mortar dr volume? How much more is to be considered for dry volume of mortar.