how to consider the lap length of a bar in IS code and
specify the code book name and clause& page number?

Answers were Sorted based on User's Feedback



how to consider the lap length of a bar in IS code and specify the code book name and clause& ..

Answer / jayavijayan k

Lap Splices :
Lap Splices shall not be used for bars larger than 36mm
dia. For larger diameters, bars may be welded. In case
welding is not practicable, lapping of bars larger than
36mm may be permitted, in which case additional spirals
should be provided around the lapped bars.

Lap Length in Tension : lap length including anchorage
value of hooks in flexural tension shall be Ld or 30D
whicever is greater and for direct tension 2Ld or 30D
whichever is greater. The straight length of lap shall not
be less than 200mm, whicever is greater.
*Ld - Development Length

Lap Length in Compression : The lap length in compression
shall be equal to the development length in compression
calculated. But shall not be less than 24D

Bars of Different Diameter : When bars of wo different
diameters are to be spliced, the lap length shall be
calculated on the basis of diameter of the smaller bar.

SOURCE : SP34 Hand Book on Concrete Reinforcing and
Detailing --- Clause 4.4.2 lap splices.

Is This Answer Correct ?    14 Yes 4 No

how to consider the lap length of a bar in IS code and specify the code book name and clause& ..

Answer / sjtbehera

it is 50d in thumb rule. but it is diffrent in diffrent
case ex. in compression and tension. lap is not greater
than 36nmm dia.

Is This Answer Correct ?    9 Yes 7 No

Post New Answer

More Civil Engineering Interview Questions

what is grid line? why are we provided small dia reinforcemen in slab against beam n column?

1 Answers  


what is the difference between composition of ceramic & glazed tiles?

2 Answers  


what is diffreant between the english bond&flamish bond

2 Answers  


What is ratio if m30

6 Answers   CCCL,


How many bricks required for 1 cu.m

7 Answers   Navayuga,






What would be the quantity of cement:Sand:Aggregate (1:2:4) requirement for slab casting measuring 1mtr x 1mtr x 0.10 mtr (4 inches)?

1 Answers  


what is mean by stripping?

2 Answers  


WHAT IS PMB IN CASE OF ROAD PAVEMENT? WHY PMB IS PREFERED THAN ORDINARY BITUMINIOUS SURFACING?

1 Answers  


Cement consumption of one cubic meter of aerocon blocks masonry?

0 Answers   Sathiapal Engineers,


is it correct method to use crush sand in concrete as per is code

1 Answers   L&T,


What is aggregate?

0 Answers  


what is ph value of water

2 Answers   Adarsh Group,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)