in pile foundation pile socketing length depend on which
factores?




Answers were Sorted based on User's Feedback



in pile foundation pile socketing length depend on which factores?..

Answer / prasadarao

generally socketing is boring further after the strata ia
hard rock generally socketing is done twice the diameter of pile

Is This Answer Correct ?    5 Yes 1 No

in pile foundation pile socketing length depend on which factores?..

Answer / gangeyyo

In pile foundations, as we all know, the strength of the pile depends on two factors, namely end-bearing and skin resistance.. Thus, the skin resistance is the factor which depends on the Pile Socketing Length and thus it depends on the type of underground soil, estimated design load, number of piles in the pile group, reinforcement used.

Is This Answer Correct ?    1 Yes 3 No

Post New Answer




More Civil Engineering Interview Questions

how we check the thickness and line of ceiling plaster.

0 Answers  


in a corner footing of a building, column lies in one corner. in this condition i want to know if the reactive pressure of soil will be uniformly distributed throughout the footing or will be uniformly varying as in the case of eccentrical loading.

0 Answers   Apex,


How to calculate crank length? How to calculate hook length?

13 Answers  


how bitumen is prepared for NH,SH &other roads

0 Answers  


Cement require for 1sqm

3 Answers   L&T, Student,






what"s the sort of beams?

0 Answers  


what is construction joint? why do we give expancion joint in building?

4 Answers   L&T, jusco,


what"s the difference between fe 415 grade steel and fe 500 grade steel? and which one is mostly used for residential and apartment constructions?

6 Answers   L&T, SkyTech,


What is the actual consumption of bindingwire Per MT for multi-storied housing construction

5 Answers  


If at site iam supposed to get M30.But by mistake i got M20 mix. How could I differentiate the mix before placing?

6 Answers  


How to estabilish reinforcement Steel rolling margin for a building projects ?

0 Answers  


1. For 10sq.m area(47 kg bitumen contain) of 45 mm thick bitumen mix layer..how much bitumen is required for 1600 sq.m and how much aggregate need for that ?? 2. And much tonnage of bitumen mix required for 10 sq.m area of 45 mm thick. Please give answer...

0 Answers  






Categories
  • Civil Engineering Interview Questions Civil Engineering (4645)
  • Mechanical Engineering Interview Questions Mechanical Engineering (3704)
  • Electrical Engineering Interview Questions Electrical Engineering (15785)
  • Electronics Communications Interview Questions Electronics Communications (2638)
  • Chemical Engineering Interview Questions Chemical Engineering (762)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (79)
  • Bio Engineering Interview Questions Bio Engineering (30)
  • Metallurgy Interview Questions Metallurgy (95)
  • Industrial Engineering Interview Questions Industrial Engineering (199)
  • Instrumentation Interview Questions Instrumentation (2882)
  • Automobile Engineering Interview Questions Automobile Engineering (171)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (41)
  • Marine Engineering Interview Questions Marine Engineering (62)
  • Power Plant Engineering Interview Questions Power Plant Engineering (170)
  • Engineering AllOther Interview Questions Engineering AllOther (1336)