how many flip flops you require for modulo 19 counter
Answers were Sorted based on User's Feedback
Answer / rahul chawre
Remember with 'n' no. of flip-flop you
can get upto max. modulo-[2^n] counter.
Therefore for modulo-19 counter
2^5 = 32 which is greater than 19 and
2^4 = 16 which is less than 19
Hence we require 5 F/F.
| Is This Answer Correct ? | 202 Yes | 12 No |
for modulo -n counter we need logn (base 2) flipflops i.e
with n no. of flip flops we can have count from 0 to 2^(n-1)
so we need 5 flip flops to have mod-19 counter.
| Is This Answer Correct ? | 42 Yes | 8 No |
Answer / raghavendra
Yes we required only 5 flipflops only.
Mod 19 means it should be count from 0 to 18 that is total
19 states . so required 5 flipflops
| Is This Answer Correct ? | 28 Yes | 8 No |
Answer / shiva
krishna answer is wrong!!!!
its so simple that it needs only 5 ff!!!
| Is This Answer Correct ? | 22 Yes | 14 No |
Answer / raghu
Mr. Kichus.. what an answer you have given yar.. Its only 5
yar........
| Is This Answer Correct ? | 18 Yes | 11 No |
There are 4 segment registers in 8086 microprocessor.Each of the segment register is of 64kb.Then (4*64)=256kb.The total memory in 8086 is 1mb.What about the rest of the memory space?
what is diffractive quality factor?
Explain the use of excitation table in digital electronics?
which taype question pattern in hr round in telecom feild.
An FM receiver has an IF frequency that is A 88MHz-108MHz range B 540kHz-1640kHz range C 455kHz D 10.7MHz
1 *2 1*3 *2*4 1*3*5 *2*4*6
Sir, I am Mrunalini studying btech 2nd year in ECE.i want to know the information about group2.how to prepare for group2? about coaching centres in hyd.what are the postings in group2? in which year i should take coaching?plz send me the informaion to my mail id.
what is the limitations of hotel management project in .net?
full form of virus?
Which power supply card required for Ultra BTS for AC 230 V input Which power supply card required for Ultra BTS for DC -48V
what is the difference between the ss7 and ip,and why we go for ip structure over ss7
is multiplexing used in 8085 or not ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)