Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is some common piping materials used to transport slurries?


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Chemical Engineering Interview Questions

Why water is not directly added to sulphuric acid for dilution?

8 Answers  


What are some characteristics of bulk solids that can affect their ability to flow properly?

0 Answers  


What is the reason for removing silicon from aluminum?

3 Answers   IOCL, ONGC,


CHEMICAL MATERIAL BALANCE – EXAMPLE 2.2 : Three hundred gallons of a mixture containing 75.0 wt % ethanol and 25 wt % water (mixture specific gravity = 0.877) and a quantity of a 40.0 wt % ethanol - 60 wt % water mixture (specific gravity = 0.952) are blended to produce a mixture containing 60.0 wt % ethanol. The specific gravity of a substance is the ratio of density of a substance compared to the density of water. The symbol of weight percent is wt %. (a) Estimate the specific gravity of the 60 % mixture by assuming that y = mx c where y is wt % ethanol, x is mixture specific gravity. Values for m and c are constants. (b) Determine the required volume of the 40 % mixture.

1 Answers  


Hi, Please give me chemical engineering paper for IOCL exam for entire written exam, GD and personel interview model questions to my email id. (chemistnathan@rediffmail.com) Rgds, Ragu

0 Answers   HAL, IOCL,


Question 90 - In the calculation of the growth of bacteria, absorbance, A in spectrophotometry is used. According to Beer-Lambert Law, A = e x l x c where A is the absorbance of the solution (no unit), l is the distance of light travels through the solution (in cm), e is the molar absorptivity or the molar extinction coefficient [ in L / (mol.cm) ]. For a particular solute and fixed path length : As / Ao = Cs / Co where Ao is the observed signal for a known concentration Co, and As is the observed signal for a sample concentration Cs. (a) For a cell concentration of 560 cells / mL, a spectrophotometre gives an absorbance reading of 1.0. A mixture of concentration 3600000 cells / mL can be diluted in several operations, with each operation having a dilution of 1:20. How many dilutions should be made so that the concentration of this mixture can be calculated within a range of A = 0.0 to 1.0. (b) In another experiment, a sample tube of 1 cm in width is used. Let A = 0.06 and e = 0.0012 ml / (cell.cm). Find the cell concentration of the sample.

1 Answers  


BIOCHEMICAL ENGINEERING INSTRUMENTATION - EXAMPLE 29.2 : (a) In order to determine the slurry volume (L) in chromatography, arrange the formula using the following parameters : slurry concentration (%), slurry volume (L), settled chromatography medium volume (L), 100. (b) In order to determine the chromatography medium volume (L) in gel filtration chromatography, arrange the formula using the following parameters : sample volume to be processed (L), chromatography medium volume (L), sample volume in percent of total column volume (%), 100.

1 Answers  


How to calculate the release flowrates from pressurized gas systems?

1 Answers   Reliance,


Question 105 - In a rigid rotor model in quantum chemistry, the moment of inertia I is given by an Equation E as I = Ma x La x La + Mc x Lc x Lc = m x L x L, where m = (Ma x Mc) / (Ma + Mc) and L = La + Lc, m is the reduced mass, Ma is the mass of a, Mc is the mass of c, La is the radius of a from point O, Lc is the radius of c from point O. Prove by simplest method that Equation E is wrong.

1 Answers  


Your favourite area of interest

7 Answers   Ambuja, CPCL, Genpact, Lilliput,


any meter avilable for measureing the Transformer Losses. ( like Voltmeter for voltage & ammiter for currenr )if yes plz give the make & supplier address, Email, Phone number.

0 Answers   Piramal Healthcare,


Why is steam added into the cracker in thermal cracking?

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)