Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the optimum period of storage of indicators?



What is the optimum period of storage of indicators?..

Answer / b.gangatharan

Indicator solutions are generally stable at room temperature and if adequate precautions are taken to avoid loss by evaporation.it can easily be used for a period of three to six months.hence an optimum period for the use of indicator solution is three months.

Thanks&regards,
B.Gangatharan,
chennai.

Is This Answer Correct ?    4 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

which procedure we follow if 6th month of accelerated sample fail?

1 Answers   Dr Reddys,


what is the principal of malvern particle sizer & its used in pharma industry

3 Answers  


What is the Calcultion of S/N Ratio.

2 Answers  


why we have to store the pH electrode in 4.01 buffer ?

1 Answers   Aurobindo, BioMax, BioSynth, Cipla, Indoco Remedies, SGS,


wt is rsd in and explain

4 Answers   Cadila, Reddy Labs,


why we inject sample TWICE in ASSAY by HPLC analysis but in RS once?

4 Answers   Aurobindo, DRL, Neuland,


what are the different methods of analysing related substances test,what are LOD AND LOQ .HOW TO REPORT IMPURITIES WHEN LOD AND LOQ LIMITS R SPECIFIED

3 Answers   Dr Reddys,


U have 4 strengths have different coating meterial which one u chose to do forced degradation stady in validation

1 Answers   Reddy Labs,


what does pH stand for?

4 Answers   Orchid,


why we use x terra columns at higher ph ?

2 Answers   Hetero,


injection volume accruacy test i calibration of hplc

3 Answers   HLL,


hii, i'm had a sample of 1L that gone through extraction & evaporation. i used 0.5ml of methanol for reconstitution before injecting the sample to HPLC. i made a calibration curve using a standard solution but now i'm confused about how to display the concentration i got from the sample. for ex. i got 0.2ug/ml how i'm gonna explane this is for the 1L ? please help .. i'll really appreciate it thanks

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)