Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In gas chromatographic analysis sometimes we use headspace, why it is required instead of manually injection?



In gas chromatographic analysis sometimes we use headspace, why it is required instead of manually ..

Answer / t.manikanta

In HSS Low boiling point Compounds are Used,In ALS High boiling point compounds are used

Is This Answer Correct ?    3 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

what is dissolution What is unit of KF? what is the significant of pH in HPlc? WHY POTASSIUM HYDROGEN PTHALATE IS USED FOR PERCHLORIC ACID? What is difference btw UV detector & RID detector?

1 Answers  


what is the differance between Analytical and semi micro balance?

2 Answers  


are there in uv lamb that is chractrestic for wavelenghth 205 nm ?????

1 Answers   Beni Suef University, Graviti Pharmaceuticals, Sri Krishna Pharmaceuticals,


Why we use Uracil for HPLC calibration in Detector wave ength accuracy test?

5 Answers  


How can you calculate manually "Slope" in pH calibration?

2 Answers   Hetero,


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

0 Answers   JBCPL,


What are the class-1 residual solvents listed in ICH guidelines?

2 Answers  


why we use pyridine to determine moisture content of acetonel

2 Answers   Lee Pharma,


what is Beer Lambert low ?

8 Answers   MAN,


What is the meaning of 624 in DB-624 Capillary column used in GC?

5 Answers   Aurobindo,


what is mass spectra ? why it is necessary ?

1 Answers  


How do you show that equal quanitities of two isomers provide the same response using a PDA

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)