Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is custom fields in waters system?



what is custom fields in waters system?..

Answer / dinesh solanki

Custom calculation is calculation done by waters softwere instead of validate excel.By custom you calculate the results online, assay,RS, single point and profiling dissolution.For this calculation we make some field and we add std, SPL wt and other required details. Initially it difficult but then it was very easy, time saving and error less calc.

Is This Answer Correct ?    10 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is definition of validation? which components are followed give detail?

0 Answers  


In UV calibration we use Holmium perchlorate solution made in 1.4M perchloric acid The question is that 1.4 M perchloric acid we make is it in water or glacial acetic acid?

4 Answers  


how to get accurate result for Residue on evaporation in purified water

0 Answers  


Principle of single pan analytical balance

0 Answers   Amneal Pharmaceuticals, Bayer, Dr Reddys,


in which situation ion pair agent require to use?

0 Answers  


Weight balance variation limit during analysis

7 Answers   Amneal Pharmaceuticals,


what is diffrence between Specific optical rotation, optical rotation?

3 Answers  


difference between instrumenent and equipment

6 Answers  


Why we more noise in PDA detector compared to UV detector?

1 Answers   Aurobindo,


How to calculate the maximum loaded sample concentration in HPLC column?

2 Answers  


In burette calibration of Karl fischer Instrument, the multiplication factor 1.00693 is using for how much ml of water dispenced. why

1 Answers  


how would you determine the acceptance criteria for cleaning validationof product A for product B?

1 Answers   Cipla, Cypher Solutions, Torrent Power,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)