Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is optical active and non active give examples?



what is optical active and non active give examples?..

Answer / falguni patel

Optically active substance:Property in which a substance is able to rotate the plane of a beam of transmitted light; a characteristic of a substance which has a chiral center.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

What is use of LOD and LOQ in validtion and give range and in calculation why we use 3.3* LOD here why we use 3.3

2 Answers   Dr Reddys, IPCA, Reddy Labs,


In which cases factor of KF Reaget got higher side

2 Answers  


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

0 Answers   GVK,


What is the calibration procedure for Malvern MS2000 particle size analyzer and acceptance criteria?

2 Answers   Reddy Labs,


What is reaction takes place when water content analysis is done

2 Answers  


what is the limit for KF Factor ,we take factor using water we will found factor between 6 to 7 ,while on KF Reagent bottle mentioned 5 mg/ml water content.if we not use dried methanol it is effect on factor.

1 Answers   Atul,


wt is rsd in and explain

4 Answers   Cadila, Reddy Labs,


What is the lab normality??

3 Answers   DRL, Tagros,


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

0 Answers  


Why we are using only KBr in IR spectrometer why not KCl

10 Answers   Dr Reddys,


why we should take dst factor for below 1%moisture samples

0 Answers   Ind Swift Laboratories,


How to calibrate glassware against std calibrated glassware?

3 Answers   Cadila, Hetero,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)