Hook up resistance decade box to temp.transmitter.



Hook up resistance decade box to temp.transmitter...

Answer / Anshul Gupta

To connect a resistance decade box to a temperature transmitter, follow these steps: Connect one lead of the decade box to a temperature sensor (RTD or thermocouple) according to the manufacturer's instructions. Connect the other lead of the decade box to the input terminals on the temperature transmitter. Adjust the decade box settings to match the resistance value of the sensor.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

NAME ANY TWO PHOTO CONDUTIVE MATERIALS?

1 Answers   DVC,


what deference between panel earth and systemearth

1 Answers   Tecnimont,


sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.

0 Answers  


Hi, am aniket, I got engineering degree in instrumentation and control, but as their were no job availabilities for engineer's post I started working as instrumentation technician I kuwait, so my question is is this technician's experience worth for getting the position of engineer?

1 Answers   Almeer Technical Services,


What is NAMUR standard and why its allways reletad with Sollenoid

2 Answers  


How do we MEASURE OR CALCULATE VELOCITY used to calculate REYNOLDS NUMBER??

3 Answers  


is any standard angle for thermowell mounting for horizontal and vertical pipe lines?

3 Answers  


What is the right procedure for adjusting the gap voltage of bently nevada vibration sensor?

3 Answers  


Where should we terminate the shield and why?

3 Answers   OPaL,


If we increase PI controller what will be action.

1 Answers   IMECO,


How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?

1 Answers   Matrix,


A DP Endress and Hauser flow transmitter is always tripping pump at low flow. set point is 74 cubic meter/hr. Thorough impulse line flushing and zero calibration has been done, yet problem persists. What do you think is the problem and how do you rectify this fault?

5 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)