Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


void volume is depending on column or not? if yes how will
you depend?



void volume is depending on column or not? if yes how will you depend?..

Answer / balaji

Yes column dependant.

Why because:Total volume of mobile phase in a fully wet
packed column- the space between the particles of the
stationary phase plus the volume within the particles

So,based on length,internal diameter and particle size of
column it varies.

Is This Answer Correct ?    17 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

0 Answers  


What r the limitatoins of uv visible spectroscopy ? Why Water use in blank standard for uv visible spectroscopy ?

4 Answers   Cipla, Reddy Labs,


what buffer you can select for acidic nature analyte and how ?

2 Answers   Dr Reddys,


Why we don't add Hcl, HNO3, H3PO4 in residue on ignition, why we add H2SO4

1 Answers  


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

0 Answers  


why we use holmiumperchlorate in calibrating uv

4 Answers   Aurobindo, DRL, MSN Pharma,


Is it necessary to validate both assay and related substances for usp official methods for products.

6 Answers   Apotex,


Nitrogen test is used for which chromatography?

1 Answers   Laurus,


In the method validation proceedure,lod & loq calculation we use the formulae for LOD=3.3*SD/slope and for LOQ=10*SD/slope,why we use 3.3 & 10 in the formulae?

1 Answers  


In Analytical method development related substance method when did follow w/w method when did follow area normalisation method

5 Answers  


What is the SOP for SOP

4 Answers   JBCPL,


what is classification of elemental impurities? what is risk assement in elemental impurities?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)