What is the Deference between Bulk density & Tap density ?

Answers were Sorted based on User's Feedback



What is the Deference between Bulk density & Tap density ? ..

Answer / me_prashant

Untapped Density = bulk density
Bulk density is the simply fill capacity of any vessels.

we take a 100ml cylinder and fill it with any
substance(Approx-x gram) and read the volume of cylinder.
then the bulk density= weight of substance/ml of cylinder.
unit = gm/ml or gm/cc
but the tapped density is that density which measure after
tapping according to monograph (USP-1, USP-2)we use it when
ever the volume of substance not to be constant.

(for USP- 1 it should be 350 stocks. and for USP -2 it
should be 250 stocks.which we use in calibration of Tap
density tester.)

Is This Answer Correct ?    28 Yes 1 No

What is the Deference between Bulk density & Tap density ? ..

Answer / spln

Bulk Density (0 taps or Untapped): As is volume in
g/ml.This is called as apparent volume.

Tapped Density: after tapping only we can measure the qty
as g/ml. As per USP two types of methods is there, Method-
I&II.
Based on the powder nature tapping are fixed.500 taps, 750
taps & 1250 taps.(Varience% is NMT 2%)
Naturally all powder grades are fixed in 1250 taps.

After 1250taps also varience is more, then go to USP-II
method or any customer requirement is there then we can use
Method-II.

Is This Answer Correct ?    18 Yes 2 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the conductivity of hplc grade water?

4 Answers  


How can we determine Moisture content of HI?

1 Answers   Cipla, Reddy Labs,


How we fix the validity period of a Normal solution and re-standardization due date

3 Answers  


Is it compulsory to prepare KBr disc with sample in identification test by FTIR?

2 Answers  


what is the differnce between GMP and CGMP

7 Answers   Shilpa Medicare,






Why we are using a Kf Factor range 4 to 6

7 Answers  


In kf constant term 16 what it is explain ?

2 Answers  


Why dissolution test is not performed in all of the products

0 Answers   Biocon, SDD,


ash or residue in that what will be there.

3 Answers  


What is gelatinization?

0 Answers   Nestle,


As per USP what is RSD limit of volumteric solution of three replicate analysis

10 Answers   Orchid,


Why using Holmium oxide in UV calibration

8 Answers   Dr Reddys, Matrix, Nakoda Chemicals, Orchid,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)