Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


hi everybody. right now i am working with thermal power
plant. our company plant is tripped because of program
corrupt. i would like to know is it possible when the plant
is running. we are using FREELANCE ABB800F CONTROLLER.

Answers were Sorted based on User's Feedback



hi everybody. right now i am working with thermal power plant. our company plant is tripped because..

Answer / sagar khandekar

i can,t understand wat r u saying,still i m working of these version,Clear all problem?

Is This Answer Correct ?    1 Yes 0 No

hi everybody. right now i am working with thermal power plant. our company plant is tripped because..

Answer / jayesh patel

hi i have exprience in petrochemical and power plants
severly in dcs system there is no chance to have failure of
program because in dcs system ther will be two system one
will be master and another will be slave the running system
will be observed by master processor and if master
processor will currupt it will shows alarm to the system
and in same time slave system come in action due to failure
of master processor and in that curcumstrances we have to
check the master processor why it was fail then if the
problem is solve then can take master processor online
manualy and check its output as same as slave processer and
if found ok then we can take in auto mode

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

types of valves

3 Answers   Bindal Papers, Kuwait Oil Company,


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device (<ping STN0149> from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

0 Answers  


what is the differnt between open loop and close loop ?

5 Answers   India Cements,


how to online calibration of remote seal tx.

0 Answers  


how to calculate static pressure in a pipe line,when we know the DP(differential pressure) in the line, area of the pipe? please any one tell me the relation between them..?

2 Answers  


What is difference b/w absolute & gauge pressure? EXPLAIN

2 Answers   IFFCO,


who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.

2 Answers  


different between calibration range and instrument range ?

2 Answers  


what type of cables are used for f&G systems and detectors, what is the standard colour?

2 Answers   Punj Lloyd Ltd,


how to do loop checking pls email to shanavaska2000@yahoo.com

2 Answers   Kentz,


What you mean by multi stage control vavles?

0 Answers  


what is the approximate cost of U tube manometer having range 1000mmwc to 1000mmwc?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)