hi everybody. right now i am working with thermal power
plant. our company plant is tripped because of program
corrupt. i would like to know is it possible when the plant
is running. we are using FREELANCE ABB800F CONTROLLER.

Answer Posted / jayesh patel

hi i have exprience in petrochemical and power plants
severly in dcs system there is no chance to have failure of
program because in dcs system ther will be two system one
will be master and another will be slave the running system
will be observed by master processor and if master
processor will currupt it will shows alarm to the system
and in same time slave system come in action due to failure
of master processor and in that curcumstrances we have to
check the master processor why it was fail then if the
problem is solve then can take master processor online
manualy and check its output as same as slave processer and
if found ok then we can take in auto mode

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why upper weighing limit of electronics balance is 90% of the total weighing capacity?

1667


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

1636


Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com

489


Why do we have earthing cable in branch cable and shield in the same cable?

2148


why use 50% lel methane gas concentration for gas detector calibration instead of 60% lel gas concentration whereas the hi alarm set at 60% lel.

2202






Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2069


How r the calculation of process line mpm.

4305


What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...

1623


Explain the working of rota meter.

761


Q1]IF THE RANGE FOR FLOW IS -35 TO 125 WHAT WILL BE THE SPAN FOR ABSOLUTE AND FOR NORMAL? Q2]HOW TO CALIBRATE CAPILLARY TYPE LT? Q3]HOW MANY ERROR CALCULATIONS ARE THERE USED IN PROCESS INDUSTRIES? Q4]HOW TO CALIBRATE TEMPERATURE TRANSMITTER? Q5] HOW TO CALIBRATE LEVEL TROLL AND HOW TO CONNECT? Q6]PLEASE TELL ME THE BASIC FOR INSTRUMENTATION WHICH IS APPLIED FOR CALIBRATION AND FOR ALL? PLEASE MAIL THE ANSWER TO honest_yes@yahoo.in

1548


Can any one send me IOCL instrumentation question papers.. i dont know the pattern of the questions and what to prepare can any one help me on this .. my email id is anwarnishil@gmail.com

1716


where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com

3058


how to calibrate and troubleshooting of leveltroll?

1657


can u plz send me technical questions asked in SCHNEIDER ELECTRICAL technical paper?

4282


What is eddy current? Describe the operating principle of proximity probe.

1760